Sorgenti per apparecchiature ibride PET/TC e SPECT/CT. Queste sorgenti possono essere utilizzate come marker per sviluppare la correzione di immagine nelle suddette tipologie di apparecchiature oppure come marker anatomici in entrambe le metodologie.

Capsule: 1” x 0.25” (D x H) white Delrin
Active dimensions: 1mm x 1mm cylinder
Suggested usage: High-resolution PET point source or fiducial marker.

Capsule: 1” x 0.25” (D x H) clear cast acrylic
Active dimensions: 1.5mm x 1.5mm cylinder
CT target: 1/4” OD bone-equivalent ring (surrounds active element)
Suggested usage: Multimodal fiducial marker for clinical image coregistration.

Capsule: 1” x 0.25” (D x H) clear cast acrylic with etched crosshairs for laser alignment

Active dimensions: 1mm diameter sphere

CT target: 2mm OD bone-equivalent ring (surrounds active element)

Suggested usage: Multimodal fiducial marker for clinical image coregistration.

Capsule: 3 x 3 x 8mm clear acrylic with Delrin plug

Active dimensions: 1 x 0.5mm (D x H) cylinder

CT target: Active element is CT-visible

Suggested usage: Multimodal fiducial marker for image coregistration, recommended for small animal studies or other situations where a small source capsule is needed.

Capsule: 1” x 0.25” (D x H) clear cast acrylic

Active dimensions: 0.25mm diameter sphere

Suggested usage: High-resolution point source or spot marker for use with scanners with resolution better than 3mm.

Capsule: 1 x 1 x 1 cm cast acrylic cube

Active dimensions: 0.25mm sphere centered in capsule

Suggested usage: NEMA NU4 resolution testing.

Capsule: 0.5” (12.7mm) dia x 0.23” (5.8mm) thick cast acrylic

Active element: .315” (8mm) dia gel with CT contrast MR/CT/radionuclide trimodal fiducial marker

Suggested usage: For clinical imaging only. Not recommended for high-resolution preclinical scanners.

Capsule: 0.157” (4mm) dia x 2.06” (52.3mm) long cast acrylic rod with threaded end
Active dimensions: 1mm dia x 0.5mm T
Nuclide: Na-22, 20 uCi (740 kBq)
Suggested usage: Dedicated source for Siemens Inveon Scanner.

Capsule: 1.75” OD x 2.36”L, polycarbonate hollow cylinder, with 4 imbedded point sources

Active dimensions: 0.5mm dia x 1mm thick point, 4 places

Suggested usage: Dedicated source for Siemens Inveon Scanner.

Capsule: 1.75” OD x 2.36”L, polycarbonate hollow cylinder, with 4 imbedded point sources

Active dimensions: 0.5mm dia x 1mm thick point, 4 places

Suggested usage: Dedicated source for Siemens Inveon Scanner.

Capsule: 0.63” OD x 1.49”L, polycarbonate hollow cylinder, with 4 imbedded point sources Active dimensions: 0.5mm dia x 1mm thick point 4 places Suggested usage: Dedicated source for Siemens Inveon Scanner.

Scarica la brochure tecnica